{"id":4527,"date":"2025-12-12T14:26:21","date_gmt":"2025-12-12T06:26:21","guid":{"rendered":"http:\/\/gaojing\/?p=4527"},"modified":"2025-12-17T08:56:55","modified_gmt":"2025-12-17T00:56:55","slug":"hot-dip-tin-coated-yellow-green-horizontal-continuous-casting-copper-clad-steel-strand","status":"publish","type":"post","link":"https:\/\/www.gro-link.com\/ar\/products\/metal-grounding-material\/hot-dip-tin-coated-yellow-green-horizontal-continuous-casting-copper-clad-steel-strand\/","title":{"rendered":"Hot-dip tin-coated yellow-green horizontal continuous casting copper-clad steel strand"},"content":{"rendered":"<p><strong>Product Features<\/strong><br \/>\nUses hot-dip tin-copper clad steel stranded wire as the inner conductor, with PVC insulation for better corrosion resistance and conductor protection. Used at the junction of grounding wires and underground pipelines, for connecting top and bottom leads, equipment grounding leads, and the grounding grid.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Technical Parameters<\/strong><\/p>\n<table width=\"100%\" border=\"1\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td width=\"254\" height=\"35\"><strong>Specifications<\/strong><\/td>\n<td width=\"251\" height=\"35\"><strong>Wire Outer Diameter<\/strong><br \/>\n<strong>(mm)<\/strong><\/td>\n<td width=\"200\" height=\"35\"><strong>Conductor Structure<\/strong><br \/>\n<strong>(mm)<\/strong><\/td>\n<td width=\"183\" height=\"35\"><strong>Cross-sectional Area<\/strong><br \/>\n<strong>(mm)<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"254\" height=\"35\">XCL-JX-16C\/PVCX<\/td>\n<td width=\"251\" height=\"35\">8.00<\/td>\n<td width=\"200\" height=\"35\">3\/2.60<\/td>\n<td width=\"183\" height=\"35\">16<\/td>\n<\/tr>\n<tr>\n<td width=\"254\" height=\"35\">XCL-JX-25C\/PVCX<\/td>\n<td width=\"251\" height=\"35\">9.50<\/td>\n<td width=\"200\" height=\"35\">3\/2.85<\/td>\n<td width=\"183\" height=\"35\">25<\/td>\n<\/tr>\n<tr>\n<td width=\"254\" height=\"35\">XCL-JX-25C\/PVCX<\/td>\n<td width=\"251\" height=\"35\">11.5<\/td>\n<td width=\"200\" height=\"35\">7\/2.50<\/td>\n<td width=\"183\" height=\"35\">35<\/td>\n<\/tr>\n<tr>\n<td width=\"254\" height=\"35\">XCL-JX-50C\/PVCX<\/td>\n<td width=\"251\" height=\"35\">13.00<\/td>\n<td width=\"200\" height=\"35\">7\/3.0<\/td>\n<td width=\"183\" height=\"35\">50<\/td>\n<\/tr>\n<tr>\n<td width=\"254\" height=\"35\">XCL-JX-70C\/PVCX<\/td>\n<td width=\"251\" height=\"35\">15.00<\/td>\n<td width=\"200\" height=\"35\">7\/3.50<\/td>\n<td width=\"183\" height=\"35\">70<\/td>\n<\/tr>\n<tr>\n<td width=\"254\" height=\"35\">XCL-JX-95C\/PVCX<\/td>\n<td width=\"251\" height=\"35\">17.50<\/td>\n<td width=\"200\" height=\"35\">7\/4.20<\/td>\n<td width=\"183\" height=\"35\">95<\/td>\n<\/tr>\n<tr>\n<td width=\"254\" height=\"35\">XCL-JX-120C\/PVCX<\/td>\n<td width=\"251\" height=\"35\">19.00<\/td>\n<td width=\"200\" height=\"35\">7\/4.70<\/td>\n<td width=\"183\" height=\"35\">120<\/td>\n<\/tr>\n<tr>\n<td width=\"254\" height=\"35\">XCL-JX-150C\/PVCX<\/td>\n<td width=\"251\" height=\"35\">21.00<\/td>\n<td width=\"200\" height=\"35\">7\/5.20<\/td>\n<td width=\"183\" height=\"35\">150<\/td>\n<\/tr>\n<tr>\n<td width=\"254\" height=\"35\">XCL-JX-185C\/PVCX<\/td>\n<td width=\"251\" height=\"35\">22.50<\/td>\n<td width=\"200\" height=\"35\">19\/3.50<\/td>\n<td width=\"183\" height=\"35\">185<\/td>\n<\/tr>\n<tr>\n<td width=\"254\" height=\"35\">XCL-JX-200C\/PVCX<\/td>\n<td width=\"251\" height=\"35\">23.50<\/td>\n<td width=\"200\" height=\"35\">19\/3.65<\/td>\n<td width=\"183\" height=\"35\">200<\/td>\n<\/tr>\n<tr>\n<td width=\"254\" height=\"35\">XCL-JX-240C\/PVCX<\/td>\n<td width=\"251\" height=\"35\">25.00<\/td>\n<td width=\"200\" height=\"35\">19\/4.00<\/td>\n<td width=\"183\" height=\"35\">240<\/td>\n<\/tr>\n<tr>\n<td width=\"254\" height=\"35\">XCL-JX-300C\/PVCX<\/td>\n<td width=\"251\" height=\"35\">27.40<\/td>\n<td width=\"200\" height=\"35\">19\/4.50<\/td>\n<td width=\"183\" height=\"35\">300<\/td>\n<\/tr>\n<tr>\n<td width=\"254\" height=\"35\">XCL-JX-400C\/PVCX<\/td>\n<td width=\"251\" height=\"35\">31.00<\/td>\n<td width=\"200\" height=\"35\">19\/5.20<\/td>\n<td width=\"183\" height=\"35\">400<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>Product Features Uses hot-dip tin-copper clad steel stranded wire as the inner conductor, with PVC insulation for better corrosion resistance and conductor protection. Used at the junction of grounding wires and underground pipelines, for connecting top and bottom leads, equipment grounding leads, and the grounding grid. &nbsp; Technical Parameters Specifications Wire Outer Diameter (mm) Conductor [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":4528,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[109],"tags":[],"acf":[],"_links":{"self":[{"href":"https:\/\/www.gro-link.com\/ar\/wp-json\/wp\/v2\/posts\/4527"}],"collection":[{"href":"https:\/\/www.gro-link.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.gro-link.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.gro-link.com\/ar\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.gro-link.com\/ar\/wp-json\/wp\/v2\/comments?post=4527"}],"version-history":[{"count":2,"href":"https:\/\/www.gro-link.com\/ar\/wp-json\/wp\/v2\/posts\/4527\/revisions"}],"predecessor-version":[{"id":4712,"href":"https:\/\/www.gro-link.com\/ar\/wp-json\/wp\/v2\/posts\/4527\/revisions\/4712"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.gro-link.com\/ar\/wp-json\/wp\/v2\/media\/4528"}],"wp:attachment":[{"href":"https:\/\/www.gro-link.com\/ar\/wp-json\/wp\/v2\/media?parent=4527"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.gro-link.com\/ar\/wp-json\/wp\/v2\/categories?post=4527"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.gro-link.com\/ar\/wp-json\/wp\/v2\/tags?post=4527"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}