{"id":4632,"date":"2025-12-16T13:50:17","date_gmt":"2025-12-16T05:50:17","guid":{"rendered":"http:\/\/gaojing\/?p=4632"},"modified":"2025-12-17T08:51:31","modified_gmt":"2025-12-17T00:51:31","slug":"absorption-grounding-device","status":"publish","type":"post","link":"https:\/\/www.gro-link.com\/fr\/products\/non-metallic-grounding-materials\/absorption-grounding-device\/","title":{"rendered":"Absorption grounding device"},"content":{"rendered":"<p><strong>Product Introduction<\/strong><br \/>\nThe main component of the absorptive grounding electrode is conductive non-metallic material. Internally, it contains a cable-like graphene lightning protection grounding body. The overall shape is cylindrical, unaffected by water, soil, acidity, alkali, or galvanic corrosion. Its main component is high-carbon graphene, which has stable chemical properties. It is connected to the graphene lightning protection grounding body using a special 316 stainless steel connecting clamp (lap clamp).<br \/>\nAbsorptive grounding electrode specifications: \u2264100*1000mm. Measured values \u200b\u200bmust not be less than nominal values.<br \/>\nThe resistance change rate of the absorptive grounding electrode after a 100kA impulse current withstand test is \u22645%. The resistance change rate of the absorptive grounding electrode after a 30A power frequency current withstand test is \u22645%.<br \/>\nThe solid-state resistivity of the absorptive grounding electrode is \u22644\u00d710-5 \u2264 183 \u00b5m.<br \/>\nWeight per unit length of the absorptive grounding electrode: 10\uff5e11 kg.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Main Standards Followed<\/strong><br \/>\nThe following latest valid standard versions shall be followed, but are not limited to:<br \/>\nGB\/T21698-2008 \"Technical Conditions for Composite Grounding Electrodes\" GB2900.1 \"Electrical Engineering Terminology\"<br \/>\nGB\/T17949 \"Guidelines for Measurement of Soil Resistivity, Grounding Impedance and Ground Potential of Grounding Systems\"<br \/>\nGB\/T16927.1 \"High Voltage Testing Technology Part 1: General Test Requirements\" GB\/T16927.2 \"High Voltage Testing Technology Part 2: Measurement Systems\"<br \/>\nGB\/T50065 \"Code for Grounding Design of AC Electrical Installations\"<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Installation Diagram<\/strong><br \/>\n<img loading=\"lazy\" class=\"\" src=\"\/wp-content\/uploads\/2025\/12\/30fc22aac43fa5080361.webp\"  width=\"770\" height=\"437\" title=\"Absorption grounding device\" alt=\"Absorption grounding device\" \/><\/p>\n<p>&nbsp;<\/p>\n<p><strong>Connection Diagram<\/strong><br \/>\n<img src=\"\/wp-content\/uploads\/2025\/12\/ce7cc84081291d6d0854.jpg\" title=\"Absorption grounding device1\" alt=\"Absorption grounding device1\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>(Note: Each set of equipment is equipped with one wire lug, a 15-meter graphene grounding electrode, two grounding electrodes, and two sets of connecting clamps. Among them: 1. The wire lug is made of 316 stainless steel; 2. The armored protection includes a 2-meter braided 316 stainless steel protective layer and an outer insulating sheath to enhance its resistance to external damage; 3. The clamps are made of 316 stainless steel to enhance corrosion resistance.)<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Technical Parameters<\/strong><\/p>\n<table border=\"1\" width=\"100%\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td width=\"179\"><strong>Test Items<\/strong><\/td>\n<td width=\"81\"><strong>Acceptance Items<\/strong><br \/>\n<strong>(Type Test)<\/strong><\/td>\n<td width=\"63\"><strong>Sampling Inspection Items<\/strong><\/td>\n<td width=\"138\"><strong>Technical Requirements<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"179\">Error between measured and nominal diameter<\/td>\n<td width=\"81\">\u221a<\/td>\n<td width=\"63\">\u221a<\/td>\n<td width=\"138\">Error \u22645%<\/td>\n<\/tr>\n<tr>\n<td width=\"179\">Resistivity of Grounding Electrode<\/td>\n<td width=\"81\">\u221a<\/td>\n<td width=\"63\">\u221a<\/td>\n<td width=\"138\">\u22643\u00d710\u207b\u2076 Q \u207b\u00b9 m<\/td>\n<\/tr>\n<tr>\n<td width=\"179\">Connection Resistance<\/td>\n<td width=\"81\">\u221a<\/td>\n<td width=\"63\"><\/td>\n<td width=\"138\">\u22644m \u207b\u00b9<\/td>\n<\/tr>\n<tr>\n<td width=\"179\">Grounding Electrode Impulse Current Withstand Test<\/td>\n<td width=\"81\">\u221a<\/td>\n<td width=\"63\"><\/td>\n<td>width=\"138\" &gt;100kA, \u22645%<\/td>\n<\/tr>\n<tr>\n<td width=\"179\">Grounding electrode power frequency current withstand test<\/td>\n<td width=\"81\">\u221a<\/td>\n<td width=\"63\"><\/td>\n<td width=\"138\">30A, \u22645%<\/td>\n<\/tr>\n<tr>\n<td width=\"179\">Corrosion test<\/td>\n<td width=\"81\">\u221a<\/td>\n<td width=\"63\"><\/td>\n<td width=\"138\">\u226410%<\/td>\n<\/tr>\n<tr>\n<td width=\"179\">Bending, tensile, and torsional strength test<\/td>\n<td width=\"81\">\u221a<\/td>\n<td width=\"63\">\u221a<\/td>\n<td width=\"138\">\u25b3R%\u226410%<\/td>\n<\/tr>\n<tr>\n<td width=\"179\">Flame retardant performance<\/td>\n<td width=\"81\">\u221a<\/td>\n<td width=\"63\"><\/td>\n<td width=\"138\">FV-0 grade<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Note: (1)\u25b3R% is the resistance change rate (test value relative to the resistance value indicated on the product nameplate).<\/strong><\/p>","protected":false},"excerpt":{"rendered":"<p>Product Introduction The main component of the absorptive grounding electrode is conductive non-metallic material. Internally, it contains a cable-like graphene lightning protection grounding body. The overall shape is cylindrical, unaffected by water, soil, acidity, alkali, or galvanic corrosion. Its main component is high-carbon graphene, which has stable chemical properties. It is connected to the graphene [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":4636,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[110],"tags":[],"acf":[],"_links":{"self":[{"href":"https:\/\/www.gro-link.com\/fr\/wp-json\/wp\/v2\/posts\/4632"}],"collection":[{"href":"https:\/\/www.gro-link.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.gro-link.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.gro-link.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.gro-link.com\/fr\/wp-json\/wp\/v2\/comments?post=4632"}],"version-history":[{"count":3,"href":"https:\/\/www.gro-link.com\/fr\/wp-json\/wp\/v2\/posts\/4632\/revisions"}],"predecessor-version":[{"id":4696,"href":"https:\/\/www.gro-link.com\/fr\/wp-json\/wp\/v2\/posts\/4632\/revisions\/4696"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.gro-link.com\/fr\/wp-json\/wp\/v2\/media\/4636"}],"wp:attachment":[{"href":"https:\/\/www.gro-link.com\/fr\/wp-json\/wp\/v2\/media?parent=4632"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.gro-link.com\/fr\/wp-json\/wp\/v2\/categories?post=4632"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.gro-link.com\/fr\/wp-json\/wp\/v2\/tags?post=4632"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}